Abstract:

The surface roughness of grit-blasted steel specimens has been measured using a non-contact method based on the correlation of speckle images derived at different incidence angles. Measurements of roughness using the speckle method agreed to within ∼±1.5 μm with independently measured average surface roughness derived using a surface profilometer.

It was noted that although the speckle analysis predicted RMS roughness, better agreement with reference roughness measurements was obtained with the speckle measurements of average roughness.

It was shown that errors in the measurement accuracy arose from lens aberrations, image miscorrelation due to the finite pixel size relative to the speckle size and shadowing of the laser beam by the surface. A sub-pixel image correlation method was demonstrated for the correction of errors associated with pixel miscorrelation.

Keywords: GRIT-BLASTED SURFACES; LASER SPECKLE; SURFACE ROUGHNESS

Document Type: Research Article

DOI: https://doi.org/10.1784/insi.2012.54.10.551

Publication date: 2012-10-01

More about this publication?
  • Access Key
  • Free ContentFree content
  • Partial Free ContentPartial Free content
  • New ContentNew content
  • Open Access ContentOpen access content
  • Partial Open Access ContentPartial Open access content
  • Subscribed ContentSubscribed content
  • Partial Subscribed ContentPartial Subscribed content
  • Free Trial ContentFree trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more