Implantable glucose sensors for diabetes monitoring

Author: E. Renard

Source: Minimally Invasive Therapy and Allied Technologies, Volume 13, Number 2, April 2004 , pp. 78-86(9)

Publisher: Informa Healthcare

Buy & download fulltext article:

OR

Price: $33.39 plus tax (Refund Policy)

Abstract:

The development of glucose sensors for clinical use is driven by the aim of blood glucose normalization in diabetic patients, and the detection of blood glucose impairment in nondiabetic subjects submitted to critical conditions. Currently available devices for continuous glucose monitoring are either minimally invasive or partly implantable, and measure subcutaneous interstitial glucose using glucose-oxidase. The signal generated is calibrated against capillary blood glucose to provide estimated blood glucose values. The three certified glucose sensing systems for clinical use: GlucoWatch® biographer, CGMS® and GlucoDay® use different techniques for glucose recovery: reverse iontophoresis, direct subcutaneous implantation and microdialysis, respectively. These devices show sufficient accuracy to identify trends of blood glucose variations, but provide information either with significant delay (GlucoWatch®) or retrospectively after computerized analysis of "Holter-style" glucose recordings (CGMS®, GlucoDay®). Only GlucoDay® can provide almost online data. Occasional use for short-term assessment of glucose control or educational purposes in diabetic subjects dominates the present clinical use of these devices. Because of the discrepancies between variations of blood and interstitial glucose levels, treatment adaptations from collected sensor data still need further assessment by capillary blood glucose measurements, while the limited biocompatibility of these systems allows only short-term recordings for a few days at most. Subcutaneous and intravenous, fully implantable, sensor models are currently under development and evaluated in clinical trials. Designed for long-term glucose sensing and permanent clinical use, these glucose sensors show promising early results in view of open-loop or closed-loop insulin delivery based upon a sensor signal.

Keywords: glucose sensor; diabetes mellitus; implantable devices; continuous monitoring; insulin delivery

Document Type: Research article

DOI: http://dx.doi.org/10.1080/13645700410026993

Affiliations: 1: Department of Endocrinology Lapeyronie Hospital Montpellier France

Publication date: 2004-04-01

More about this publication?
Related content

Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content

Text size:

A | A | A | A
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages. print icon Print this page